Microcell is typically used toextend coverage to areas where Macro cell signals do not reach well, or to addnetwork capacity in hotspot.


ABUIABAEGAAgyPCA7QUolJ7ksgcw2AM4nAI
ABUIABAEGAAg9vGA7QUozuXUswcwuBc41A4

n   Stateof art “green” technology

n   Build-inbaseband unit

n   Supportboth Ethernet and SFP backhaul

n   Smallsize and weight

n   Self-OrganizedNetwork Plug and Play

ØSelf-configuration:Physical Cell Identity(PCI) auto configuration, TransmissionPower Management,Automatic Neighbor Relation(ARO)

Ø   Self-optimization:Mobility robustness optimization(MRO),Mobility load balancing(MLB), Capacity and coverage optimization(CCO)

n   Support TR-069, web GUI based configuration andfirmware upgrade


Technical   Specifications

Requirements

Frequency   Band

B1 (21102170MHz)   B2 (19301990MHz)

B3 (18051880MHz)   B5 (869894MHz)

B8(925960MHz)     B20(791821MHz)   

B28 (758803MHz)    B41 (24962690MHz)

B42(34003600MHz)   B48(35503700MHz CBRS)

Channel

4T4R

RF   Transmission Power

4*2W/5W/10W

Max   Tx EVM(64QAM)

<   4.5%

Rx   sensitivity

-104dBm

Frequency   Error

±0.05ppm

Throughput

FDD:   300Mbps/50Mbps

TDD:   240Mbps/30Mbps

Connect   User Number

192

Synchronization   Mechanisms

Support   1588v2/GPS/NL

IP   Rating

IP66

Power   Supply

AC90V~286V/DC-48V

Operating   Temperature

-40~ +55

Operating   Humidity

5%   to 95%RH, non condensing